DRUCK Digital Test Gauge
DRUCK Digital Test Gauge
Model: DPI104
Brand: druck
Origin: UK/CHINA
요약
Druck DPI 104 Intrinsically Safe Digital Test Pressure Gauge. 0.05 full scale accuracy. Range 0 to 1000 psig, 1/4 inch NPT male connection
- 0.05% full scale (FS) accuracy
- Pressure ranges to 1,000 psi
- Eleven selectable pressure units
- Large, easy-to-read display with five-digit resolution
- % pressure indication and additional bar graph for quick visual reference
- Temperature compensated accuracy from 14°F to 122°F (-10°C to 50°C)
- 0 to 5V analog output
- Pressure switch test
- Minimum/maximum, tare and alarm functions
- IDOS compatible and RS232 serial interface
- Free of charge monitoring and control software
- Stainless steel or Inconel pressure cavity for aggressive media
- Accuracy
0.05% FS including non-linearity, hysteresis, repeatability and temperature effects from 14°F to 122°F (-10°C to 50°C) - Resolution
Maximum five digits - Burst Pressure
Burst pressure is 2x working pressure (exception, 20,000 psi (1400 bar); burst pressure 29,000 psi (2000 bar). - Selectable Pressure Units
kPa, MPa, kg/cm2, psi, mbar, bar, inHg, inH2O, mH2O, mmH2O and mmHg - Display
- Pressure reading: 5 digits with 0.5 in (12.7 mm) character height
- Full scale indicator: 2.5 digits with 0.25 in (6.35 mm) character height
- Pressure Bar Graph
In addition to the numeric pressure indication, the DPI 104 LCD display contains a circular twenty segment bar graph to provide the user with a quick visual estimation of pressure from 0 to 100% full scale output. The bar graph increments represent 5% of the user- selectable range. - Display Update
Two times per second - Minimum/Maximum Values
The minimum and maximum pressure values can be displayed on the DPI 104. This function can be enabled/disabled, and reset by the user. - Switch Test
The DPI 104 features a switch test function that will capture and display the open and closed values from an external pressure switch. Maximum switch impedance 200 Ω. - Voltage Output
The DPI 104 can be programmed to provide a 0 to 5 V output signal that can be configured as directly proportional to the pressure shown in the display or set to a fixed value. The voltage output mode provides 0.1% FS accuracy from 50 mV to 5 V. - Alarm Output
The alarm output consists of an open drain field effect transistor (maximum current 250 mA, maximum voltage 24 VDC). - Adjustable Mounting Positions
For added convenience, the DPI 104 housing will rotate 320° around the pressure fitting and the faceplate can be rotated in any orientation for optimum visibility. - Menu Lock
To guard against unauthorized menu access, the DPI 104 features a menu and tare lock function. - RS232 Interface
Serial communications are provided to allow transfer of data to a PC with the optional serial lead (IA4090-2-V0). Using this link, all menu commands and display data are available via an ASCII command set or the optional SiCal Pro Software. - Network Capability
Up to 99 DPI 104 instruments can be connected together in a daisy chain-configured network. - Universal Pressure Module (UPM) Capability
UPM modules can be connected to the DPI 104 to enhance the accuracy and extend the pressure range.
Druck DPI 104 General Specifications | |
Display | LCD |
EMC | EN 61326-1 |
Electrical Safety | EN 61010-1 |
Pressure Safety | Pressure Equipment Directive - Class: Sound Engineering Practice (SEP). |
Power supply | 9V, IEC 6LR61, ANSI/NEDA 1604 battery, OR use an external 12-24 Vdc 50mA supply. |
Operating temperature | -10 to 50°C (14 to 122°F). |
Storage temperature | -20 to 70°C (-4 to 158°F). |
Ingress Protection | IP65 *. |
Operating Humidity | 0 to 95% relative humidity (RH) non-condensing |
Vibration | Def Stan 66-31, 8.4 cat III. |
Operating altitude | 2000 metres (6560 ft). |
Pollution degree | 2 |
Switch input | Maximum impedance: 200Ω (mechanical contact only). |
Alarm output | Type: Open drain Field Effect Transistor (FET) Maximum (mA): 250 mA; Maximum (V): 24 Vdc. |
Analog output | 0.05 to 5 Vdc; Minimum load: 500 Ω; Accuracy: 0.1% FS at 20°C (68°F) - user mode only. Temperature coefficient: 0.007% FS / °C (0.0039% FS / °F). |
Battery life | Up to one year for pressure measurements: Au (power save facility) - On; maximum/minimum, alarm, Vout, switch - all set to OFF. |
RS232/Network capacity | For: IDOS UPM, external software, or up to 99 units in series (‘daisy chain’). |
Materials | Case: Acrylonitrile Butadiene Styrene (ABS) ** |
Approved | CE Marked. |
Size | Diameter = 95 mm (3.74 in); Depth = 55 mm (2.2 in) Typical length (with connector) ≈ 120 mm (4.7 in). |
Weight | 350g (12.5 oz). |
어플리케이션
- Accuracy
0.05% FS including non-linearity, hysteresis, repeatability and temperature effects from 14°F to 122°F (-10°C to 50°C) - Resolution
Maximum five digits - Burst Pressure
Burst pressure is 2x working pressure (exception, 20,000 psi (1400 bar); burst pressure 29,000 psi (2000 bar). - Selectable Pressure Units
kPa, MPa, kg/cm2, psi, mbar, bar, inHg, inH2O, mH2O, mmH2O and mmHg - Display
- Pressure reading: 5 digits with 0.5 in (12.7 mm) character height
- Full scale indicator: 2.5 digits with 0.25 in (6.35 mm) character height
- Pressure Bar Graph
In addition to the numeric pressure indication, the DPI 104 LCD display contains a circular twenty segment bar graph to provide the user with a quick visual estimation of pressure from 0 to 100% full scale output. The bar graph increments represent 5% of the user- selectable range. - Display Update
Two times per second - Minimum/Maximum Values
The minimum and maximum pressure values can be displayed on the DPI 104. This function can be enabled/disabled, and reset by the user. - Switch Test
The DPI 104 features a switch test function that will capture and display the open and closed values from an external pressure switch. Maximum switch impedance 200 Ω. - Voltage Output
The DPI 104 can be programmed to provide a 0 to 5 V output signal that can be configured as directly proportional to the pressure shown in the display or set to a fixed value. The voltage output mode provides 0.1% FS accuracy from 50 mV to 5 V. - Alarm Output
The alarm output consists of an open drain field effect transistor (maximum current 250 mA, maximum voltage 24 VDC). - Adjustable Mounting Positions
For added convenience, the DPI 104 housing will rotate 320° around the pressure fitting and the faceplate can be rotated in any orientation for optimum visibility. - Menu Lock
To guard against unauthorized menu access, the DPI 104 features a menu and tare lock function. - RS232 Interface
Serial communications are provided to allow transfer of data to a PC with the optional serial lead (IA4090-2-V0). Using this link, all menu commands and display data are available via an ASCII command set or the optional SiCal Pro Software. - Network Capability
Up to 99 DPI 104 instruments can be connected together in a daisy chain-configured network. - Universal Pressure Module (UPM) Capability
UPM modules can be connected to the DPI 104 to enhance the accuracy and extend the pressure range.
명세서
Druck DPI 104 General Specifications | |
Display | LCD |
EMC | EN 61326-1 |
Electrical Safety | EN 61010-1 |
Pressure Safety | Pressure Equipment Directive - Class: Sound Engineering Practice (SEP). |
Power supply | 9V, IEC 6LR61, ANSI/NEDA 1604 battery, OR use an external 12-24 Vdc 50mA supply. |
Operating temperature | -10 to 50°C (14 to 122°F). |
Storage temperature | -20 to 70°C (-4 to 158°F). |
Ingress Protection | IP65 *. |
Operating Humidity | 0 to 95% relative humidity (RH) non-condensing |
Vibration | Def Stan 66-31, 8.4 cat III. |
Operating altitude | 2000 metres (6560 ft). |
Pollution degree | 2 |
Switch input | Maximum impedance: 200Ω (mechanical contact only). |
Alarm output | Type: Open drain Field Effect Transistor (FET) Maximum (mA): 250 mA; Maximum (V): 24 Vdc. |
Analog output | 0.05 to 5 Vdc; Minimum load: 500 Ω; Accuracy: 0.1% FS at 20°C (68°F) - user mode only. Temperature coefficient: 0.007% FS / °C (0.0039% FS / °F). |
Battery life | Up to one year for pressure measurements: Au (power save facility) - On; maximum/minimum, alarm, Vout, switch - all set to OFF. |
RS232/Network capacity | For: IDOS UPM, external software, or up to 99 units in series (‘daisy chain’). |
Materials | Case: Acrylonitrile Butadiene Styrene (ABS) ** |
Approved | CE Marked. |
Size | Diameter = 95 mm (3.74 in); Depth = 55 mm (2.2 in) Typical length (with connector) ≈ 120 mm (4.7 in). |
Weight | 350g (12.5 oz). |