HIOKI MEMORY HiLOGGER
HIOKI MEMORY HiLOGGER
Model: LR8450-01 (Wireless LAN model)
Brand: Hioki
Origin: Japan
Summary
1ms Sampling Portable Logger Expandable to 330 Channels with Your Choice of Plug-in or Wireless Input Modules
Hioki Memory HiLoggers are high-speed data loggers for recording multiple channels of voltage, temperature, resistance or humidity signals, some models providing complete isolation between channels and strong noise resistance. The LR8450-01 offers 1ms sampling across up to 330 channels, and can be paired with 10 different types of plug-in or wireless input units. Collect data from wireless modules installed in remote or confined locations via a LAN connection. New input modules measure strain and distortion, ideal for automotive applications involving the evaluation of vehicle components as well as robotic equipment.
Stable Logging - Even at High Voltages and Frequencies. Minimize the Effects of Noise.
The LR8450 reduces the effects of noise to deliver stable logging, even at high voltages and frequencies.
Legacy data loggers could not log temperature accurately in noisy environments due to the effects of high frequencies, which caused values to shift or fluctuate significantly.
The new Hioki Memory HiLogger LR8450 uses a revamped design to dramatically reduce the effects of high-frequency noise, and is ideal for temperature logging of inverters and batteries.
Connect strain gages directly and make measurements in as little as 1 ms.
The Memory HiLogger LR8450 is a data logger that can measure stress via directly connected strain gages. Capable of recording at frequencies on the order of dozens of hertz thanks to sampling at up to 1 ms, the LR8450 is ideal for measuring stress and load on moving parts and strain on components such as brakes and pipes. And because it can accommodate a mix of various measurement units, the LR8450 can simultaneously measure strain, temperature, and voltage as necessary.
Add a total of up to 7 wireless units for a maximum of 330 channels
With four U8552 VOLTAGE/TEMP Units and seven LR8532 WIRELESS VOLTAGE/TEMP Units, you can measure a total of 330 channels.
Analog 600 CH Synchronous Sampling Measurement [Since V2.10]
Synchronized sampling up to 5 plug-in modules (600 analog channels) can be measured when multiple LR8450's external sync terminals (SYNC.IN, SYNC.OUT) are connected.
Note: This function cannot be used when wireless modules are connected.
Sample output from a variety of sensors, including 1 ms pressure sensors
Measures at a sampling rate of up to 1 ms.
1 ms sampling rate is the best match to measure sensor outputs with a frequency response of under 100 Hz, for example pressure and vibration sensors.
Measure strain with a 1 ms sampling rate
Connect strain gauges directly and measure at a sampling rate of up to 1 ms.
Strain gauges tend to have long, thin wires that are easily broken, but that potential pitfall can be avoided by using wireless units so that wire length is minimized.
Measure temperature near an inverter or battery
Measures at a sampling rate of up to 10 ms.
Make measurements in locations where it would be difficult to route wires
Work time can be reduced by using the LR8450-01 and wireless units, since only minimal wiring is required. If the measurement target is located in a lab, this approach eliminates the need to string wire and drill holes in the walls of the monitoring room where data is checked.
Accuracy guaranteed: 1 year
Max. number of connectable modules | 4 plug-in input modules + 7 wireless input modules | |||||
---|---|---|---|---|---|---|
Connectable modules (Plug-in modules) |
U8550, U8551, U8552, U8553, U8554, U8555 (U8555: supported V2.00 or later) |
|||||
Connectable modules (Wireless modules) |
LR8530, LR8531, LR8532, LR8533, LR8534, LR8535 (LR8535: supported V2.00 or later) |
|||||
No. of measurement channels | Up to 120 ch with plug-in input modules, up to 330 ch with plug-in input modules and wireless input modules | |||||
Pulse/logic input | [Number of ch] 8 ch (common GND, non-isolated, exclusive setting for pulse/logic input for individual channels) [Adaptive input format] Non-voltage contact, open collector, or voltage input [Count] 0 to 1000 M pulse, 1 pulse resolution [Rotational speed] 0 to 5000/n (r/s), 1/n (r/s) resolution, 0 to 300,000/n (r/min.), 1/n (r/min.) resolution, n: Number of pulses per rotation (1 to 1000) [Logic input] Records 1 or 0 for each recording interval |
|||||
Recording intervals | 1 ms*, 2 ms*, 5 ms* (*: Can be set only when using 1 ms/S modules), 10 ms to 1 hour, 22 selections (Data refresh interval can be set for each unit | |||||
Data storage | SD Memory Card/USB Drive (user-selectable) (Only storage media sold by HIOKI are guaranteed for operation) |
|||||
LAN interface | 100BASE-TX / 1000BASE-T, DHCP, DNS support, Functions: Data acquisition, condition settings used with the Logger Utility software, configuring settings and controlling recording using communications commands, FTP server / FTP client, HTTP server, Email transmission, NTP client |
|||||
Wireless LAN interface | IEEE 802.11b/g/n Communications range: 30 m, line of sight Encryption function: WPA-PSK/WPA2-PSK, TKIP/AES Usable channels: 1 to 11 Supported modes: Wireless unit connectivity, access point, station Functions: Configuring settings and controlling recording using communications commands, FTP server / client, HTTP server, Email transmission, NTP client |
|||||
USB interface | Series A receptacle × 2: USB 2.0 compliant (USB drive, keyboard, or hub)) Series mini-B receptacle × 1: Data acquisition, condition settings used with the Logger Utility, configuring settings and controlling recording using communications commands, transferring data from a connected SD Memory Card to a computer |
|||||
SD card slot | SD standard-compliant slot × 1 (with SD memory card/SDHC memory card support), Guaranteed-operation options: Z4001, Z4003 | |||||
Display | 7 inch TFT color liquid crystal display (WVGA 800 × 480 pixel) | |||||
Functions | Save waveform data in real time to the SD memory card or USB drive, numerical value calculations, waveform calculations, 8ch alarm output, voltage output ×2 (5 V /12 V /24 V selectable) | |||||
Power supply | [AC adapter] Using the Z1014 (100 to 240 V AC, 50/60 Hz), 95 VA Max. (including AC adapter), 28 VA Max. (exclusive of AC adapter) [Battery Pack] Using the Z1007 (accommodates 2 batteries), continuous use 4 hr (reference value for 2 pieces), 20 VA Max. [External power] 10 to 30 V DC, 28 VA Max. (Please contact your HIOKI distributor for connection cord) |
|||||
Dimensions and mass | Without any modules: 272 mm (10.71 in) W × 145 mm (5.71 in) H × 43 mm (1.69 in) D (excluding protrusions), 1108 g (39.1 oz) (excluding battery pack) With 2 modules: 272 mm (10.71 in) W × 198 mm (7.80 in) H × 63 mm (2.48 in) D (excluding protrusions) With 4 modules: 272 mm (10.71 in) W × 252 mm (9.92 in) H × 63 mm (2.48 in) D (excluding protrusions) |
|||||
Included accessories | Quick Start Manual ×1, LOGGER Application Disc (Quick Start Manual, Instruction Manual, Logger Utility, Logger Utility Instruction Manual, Communication Instruction Manual) ×1, USB Cable ×1, AC Adapter Z1014 ×1, Precautions Concerning Use of Equipment that Emits Radio Waves ×1,CAN editor, CAN editor instruction manual |
Countries and regions where wireless operation is currently supported (LR8450-01)
Last update: Jan. 2022
Countries and regions where wireless operation is currently supported | Australia, Austria, Bangladesh, Belgium, Brazil, Bulgaria, Canada, Chile, China, Colombia, Croatia, Cyprus, Czech Republic, Denmark, Egypt, Estonia, Finland, France, Georgia, Germany, Greece, Hong Kong, Hungary, Iceland, India, Indonesia, Ireland, Israel(*1), Italy, Japan, Kenya, Korea, Latvia, Liechtenstein, Lithuania, Luxembourg, Macao, Malaysia(*2), Malta, Myanmar, Netherlands, New Caledonia, New Zealand, Norway, Philippines, Poland, Portugal, Romania, Saudi Arabia, Singapore, Slovakia, Slovenia, Spain, Sweden, Switzerland, Taiwan, Thailand, Turkey, United Kingdom, United Arab Emirates (UAE), United States, Viet Nam *1: Wireless input modules are not supported. (LR8530, LR8531, LR8532, LR8533, LR8534, LR8535) *2: The approval is valid for specific distributor or importer only. Please be consulted by our sales office for details. |
|||||
---|---|---|---|---|---|---|
Note | Use of devices that emit radio radiation requires approval in the country of use. Thus, use of the instrument in a country or region where they have not been approved may be subject to penalty as a violation of law. |
Application
Stable Logging - Even at High Voltages and Frequencies. Minimize the Effects of Noise.
The LR8450 reduces the effects of noise to deliver stable logging, even at high voltages and frequencies.
Legacy data loggers could not log temperature accurately in noisy environments due to the effects of high frequencies, which caused values to shift or fluctuate significantly.
The new Hioki Memory HiLogger LR8450 uses a revamped design to dramatically reduce the effects of high-frequency noise, and is ideal for temperature logging of inverters and batteries.
Connect strain gages directly and make measurements in as little as 1 ms.
The Memory HiLogger LR8450 is a data logger that can measure stress via directly connected strain gages. Capable of recording at frequencies on the order of dozens of hertz thanks to sampling at up to 1 ms, the LR8450 is ideal for measuring stress and load on moving parts and strain on components such as brakes and pipes. And because it can accommodate a mix of various measurement units, the LR8450 can simultaneously measure strain, temperature, and voltage as necessary.
Add a total of up to 7 wireless units for a maximum of 330 channels
With four U8552 VOLTAGE/TEMP Units and seven LR8532 WIRELESS VOLTAGE/TEMP Units, you can measure a total of 330 channels.
Analog 600 CH Synchronous Sampling Measurement [Since V2.10]
Synchronized sampling up to 5 plug-in modules (600 analog channels) can be measured when multiple LR8450's external sync terminals (SYNC.IN, SYNC.OUT) are connected.
Note: This function cannot be used when wireless modules are connected.
Sample output from a variety of sensors, including 1 ms pressure sensors
Measures at a sampling rate of up to 1 ms.
1 ms sampling rate is the best match to measure sensor outputs with a frequency response of under 100 Hz, for example pressure and vibration sensors.
Measure strain with a 1 ms sampling rate
Connect strain gauges directly and measure at a sampling rate of up to 1 ms.
Strain gauges tend to have long, thin wires that are easily broken, but that potential pitfall can be avoided by using wireless units so that wire length is minimized.
Measure temperature near an inverter or battery
Measures at a sampling rate of up to 10 ms.
Make measurements in locations where it would be difficult to route wires
Work time can be reduced by using the LR8450-01 and wireless units, since only minimal wiring is required. If the measurement target is located in a lab, this approach eliminates the need to string wire and drill holes in the walls of the monitoring room where data is checked.
Specifications
Accuracy guaranteed: 1 year
Max. number of connectable modules | 4 plug-in input modules + 7 wireless input modules | |||||
---|---|---|---|---|---|---|
Connectable modules (Plug-in modules) |
U8550, U8551, U8552, U8553, U8554, U8555 (U8555: supported V2.00 or later) |
|||||
Connectable modules (Wireless modules) |
LR8530, LR8531, LR8532, LR8533, LR8534, LR8535 (LR8535: supported V2.00 or later) |
|||||
No. of measurement channels | Up to 120 ch with plug-in input modules, up to 330 ch with plug-in input modules and wireless input modules | |||||
Pulse/logic input | [Number of ch] 8 ch (common GND, non-isolated, exclusive setting for pulse/logic input for individual channels) [Adaptive input format] Non-voltage contact, open collector, or voltage input [Count] 0 to 1000 M pulse, 1 pulse resolution [Rotational speed] 0 to 5000/n (r/s), 1/n (r/s) resolution, 0 to 300,000/n (r/min.), 1/n (r/min.) resolution, n: Number of pulses per rotation (1 to 1000) [Logic input] Records 1 or 0 for each recording interval |
|||||
Recording intervals | 1 ms*, 2 ms*, 5 ms* (*: Can be set only when using 1 ms/S modules), 10 ms to 1 hour, 22 selections (Data refresh interval can be set for each unit | |||||
Data storage | SD Memory Card/USB Drive (user-selectable) (Only storage media sold by HIOKI are guaranteed for operation) |
|||||
LAN interface | 100BASE-TX / 1000BASE-T, DHCP, DNS support, Functions: Data acquisition, condition settings used with the Logger Utility software, configuring settings and controlling recording using communications commands, FTP server / FTP client, HTTP server, Email transmission, NTP client |
|||||
Wireless LAN interface | IEEE 802.11b/g/n Communications range: 30 m, line of sight Encryption function: WPA-PSK/WPA2-PSK, TKIP/AES Usable channels: 1 to 11 Supported modes: Wireless unit connectivity, access point, station Functions: Configuring settings and controlling recording using communications commands, FTP server / client, HTTP server, Email transmission, NTP client |
|||||
USB interface | Series A receptacle × 2: USB 2.0 compliant (USB drive, keyboard, or hub)) Series mini-B receptacle × 1: Data acquisition, condition settings used with the Logger Utility, configuring settings and controlling recording using communications commands, transferring data from a connected SD Memory Card to a computer |
|||||
SD card slot | SD standard-compliant slot × 1 (with SD memory card/SDHC memory card support), Guaranteed-operation options: Z4001, Z4003 | |||||
Display | 7 inch TFT color liquid crystal display (WVGA 800 × 480 pixel) | |||||
Functions | Save waveform data in real time to the SD memory card or USB drive, numerical value calculations, waveform calculations, 8ch alarm output, voltage output ×2 (5 V /12 V /24 V selectable) | |||||
Power supply | [AC adapter] Using the Z1014 (100 to 240 V AC, 50/60 Hz), 95 VA Max. (including AC adapter), 28 VA Max. (exclusive of AC adapter) [Battery Pack] Using the Z1007 (accommodates 2 batteries), continuous use 4 hr (reference value for 2 pieces), 20 VA Max. [External power] 10 to 30 V DC, 28 VA Max. (Please contact your HIOKI distributor for connection cord) |
|||||
Dimensions and mass | Without any modules: 272 mm (10.71 in) W × 145 mm (5.71 in) H × 43 mm (1.69 in) D (excluding protrusions), 1108 g (39.1 oz) (excluding battery pack) With 2 modules: 272 mm (10.71 in) W × 198 mm (7.80 in) H × 63 mm (2.48 in) D (excluding protrusions) With 4 modules: 272 mm (10.71 in) W × 252 mm (9.92 in) H × 63 mm (2.48 in) D (excluding protrusions) |
|||||
Included accessories | Quick Start Manual ×1, LOGGER Application Disc (Quick Start Manual, Instruction Manual, Logger Utility, Logger Utility Instruction Manual, Communication Instruction Manual) ×1, USB Cable ×1, AC Adapter Z1014 ×1, Precautions Concerning Use of Equipment that Emits Radio Waves ×1,CAN editor, CAN editor instruction manual |
Countries and regions where wireless operation is currently supported (LR8450-01)
Last update: Jan. 2022
Countries and regions where wireless operation is currently supported | Australia, Austria, Bangladesh, Belgium, Brazil, Bulgaria, Canada, Chile, China, Colombia, Croatia, Cyprus, Czech Republic, Denmark, Egypt, Estonia, Finland, France, Georgia, Germany, Greece, Hong Kong, Hungary, Iceland, India, Indonesia, Ireland, Israel(*1), Italy, Japan, Kenya, Korea, Latvia, Liechtenstein, Lithuania, Luxembourg, Macao, Malaysia(*2), Malta, Myanmar, Netherlands, New Caledonia, New Zealand, Norway, Philippines, Poland, Portugal, Romania, Saudi Arabia, Singapore, Slovakia, Slovenia, Spain, Sweden, Switzerland, Taiwan, Thailand, Turkey, United Kingdom, United Arab Emirates (UAE), United States, Viet Nam *1: Wireless input modules are not supported. (LR8530, LR8531, LR8532, LR8533, LR8534, LR8535) *2: The approval is valid for specific distributor or importer only. Please be consulted by our sales office for details. |
|||||
---|---|---|---|---|---|---|
Note | Use of devices that emit radio radiation requires approval in the country of use. Thus, use of the instrument in a country or region where they have not been approved may be subject to penalty as a violation of law. |