HIOKI BATTERY HiTESTER
HIOKI BATTERY HiTESTER
Model: BT3564
Brand: Hioki
Origin: Japan
요약
- 1000V Maximum Input Voltage, High-Voltage Battery Tester for Measuring EV and PHEV Battery Packs
- Hioki benchtop battery testers support simultaneous high-speed measurement of the internal resistance and battery voltage of EV and PHEV battery packs. The BT3564 Battery HiTester can measure pack voltage and total resistance, as well as bus bar resistance up to 1000V.
Maximum input voltage 1000V. High voltage battery tester for EV and PHEV.
The BT3564 simultaneously measures both internal resistance and battery voltage with an input voltage of up to 1000 V. This battery tester is perfect for shipping and receiving inspections of battery packs ranging from increasingly higher voltage EV and PHEV batteries to home storage batteries.
Probe supports 1000 V and high voltage battery packs (option)
Safely and smoothly measure high voltage battery packs with the 1000 V probe.
Built-in spark discharge reduction function
Spark discharges become more likely with measurements of higher voltages.The BT3564 limits the current that flows when contacting battery packs, thus reducing spark discharges.
Analog output function
Complete with a built-in resistance value analog output function. Combine it with a recorder or logger for total resistance value monitoring.
Max. applied measurement voltage |
± 1000 VDC rated input voltage ± 1000 VDC max. rated voltage to earth |
|||||
Resistance measurement ranges | 3 mΩ (max. display 3.1000 mΩ, resolution 0.1 μΩ) to 3 kΩ (max. display 3.1000 kΩ, resolution 0.1 Ω), 7 ranges Accuracy: ±0.5 % rdg. ±5 dgt. (30 mΩ to 3 kΩ range), ±0.5 % rdg. ±10 dgt. (3 mΩ range) Testing source frequency: 1 kHz ±0.2 Hz, testing current: 100 mA (3 mΩ range) to 10 μA (3.000 kΩ range) Open terminal Voltage: 25 V peak (3/30 mΩ ranges), 7 V peak (300 mΩ range), 4 V peak (3 Ω to 3.000 kΩ range) |
|||||
Voltage measurement ranges | 10 V DC (resolution: 10 µV) to 1000V DC (resolution: 1 m V), 3 ranges Accuracy: ±0.01 % rdg. ±3 dgt. |
|||||
Display | 31000 full digits (resistance), 999999 full digits (voltage, 1000 V range: 999999 or 110000), LED | |||||
Sampling time | FAST: 12 ms, MEDIUM: 35 ms, SLOW: 253 ms (Typ., sampling time depends on supply frequency settings and function.) |
|||||
Total measurement time | Response time + sampling time (Response time for both resistance and voltage are reference value of about 700 ms, depends on measurement object.) | |||||
Comparator functions | Judgment result: Hi/IN/Lo (resistance and voltage judged independently) Setting: Upper and lower limit, Deviation (%) from reference value Logical ANDed result: PASS/FAIL, calculates the logical AND of resistance and voltage judgment results. Result display, beeper, or external I/O output (open-collector, 35 V, 50 mA DC max.) |
|||||
Analog output | Measured resistance (displayed value, from 0 to 3.1 V DC) | |||||
Interfaces | External I/O, RS-232C, Printer (RS-232C), GP-IB | |||||
Power supply | 100 to 240 V AC, 50/60 Hz, 30 VA max. | |||||
Dimensions and mass | 215 mm (8.46 in) W × 80 mm (3.29 in) H × 295 mm (12.95 in) D, 2.4 kg (84.7 oz) | |||||
Included accessories | Instruction manual ×1, Power cord ×1 , Operating Precautions ×1 |
어플리케이션
Maximum input voltage 1000V. High voltage battery tester for EV and PHEV.
The BT3564 simultaneously measures both internal resistance and battery voltage with an input voltage of up to 1000 V. This battery tester is perfect for shipping and receiving inspections of battery packs ranging from increasingly higher voltage EV and PHEV batteries to home storage batteries.
Probe supports 1000 V and high voltage battery packs (option)
Safely and smoothly measure high voltage battery packs with the 1000 V probe.
Built-in spark discharge reduction function
Spark discharges become more likely with measurements of higher voltages.The BT3564 limits the current that flows when contacting battery packs, thus reducing spark discharges.
Analog output function
Complete with a built-in resistance value analog output function. Combine it with a recorder or logger for total resistance value monitoring.
명세서
Max. applied measurement voltage |
± 1000 VDC rated input voltage ± 1000 VDC max. rated voltage to earth |
|||||
Resistance measurement ranges | 3 mΩ (max. display 3.1000 mΩ, resolution 0.1 μΩ) to 3 kΩ (max. display 3.1000 kΩ, resolution 0.1 Ω), 7 ranges Accuracy: ±0.5 % rdg. ±5 dgt. (30 mΩ to 3 kΩ range), ±0.5 % rdg. ±10 dgt. (3 mΩ range) Testing source frequency: 1 kHz ±0.2 Hz, testing current: 100 mA (3 mΩ range) to 10 μA (3.000 kΩ range) Open terminal Voltage: 25 V peak (3/30 mΩ ranges), 7 V peak (300 mΩ range), 4 V peak (3 Ω to 3.000 kΩ range) |
|||||
Voltage measurement ranges | 10 V DC (resolution: 10 µV) to 1000V DC (resolution: 1 m V), 3 ranges Accuracy: ±0.01 % rdg. ±3 dgt. |
|||||
Display | 31000 full digits (resistance), 999999 full digits (voltage, 1000 V range: 999999 or 110000), LED | |||||
Sampling time | FAST: 12 ms, MEDIUM: 35 ms, SLOW: 253 ms (Typ., sampling time depends on supply frequency settings and function.) |
|||||
Total measurement time | Response time + sampling time (Response time for both resistance and voltage are reference value of about 700 ms, depends on measurement object.) | |||||
Comparator functions | Judgment result: Hi/IN/Lo (resistance and voltage judged independently) Setting: Upper and lower limit, Deviation (%) from reference value Logical ANDed result: PASS/FAIL, calculates the logical AND of resistance and voltage judgment results. Result display, beeper, or external I/O output (open-collector, 35 V, 50 mA DC max.) |
|||||
Analog output | Measured resistance (displayed value, from 0 to 3.1 V DC) | |||||
Interfaces | External I/O, RS-232C, Printer (RS-232C), GP-IB | |||||
Power supply | 100 to 240 V AC, 50/60 Hz, 30 VA max. | |||||
Dimensions and mass | 215 mm (8.46 in) W × 80 mm (3.29 in) H × 295 mm (12.95 in) D, 2.4 kg (84.7 oz) | |||||
Included accessories | Instruction manual ×1, Power cord ×1 , Operating Precautions ×1 |