Desktop Force Amplifier
Desktop Force Amplifier
Model: FA Plus2/eFA Plus2
Brand: Imada
Origin:
Summary
Desktop force amplifier is ideal for integration into facility, and can be used with variety of load cells. There are various inputs/outputs, and they can be used as part of factory automation equipment. 2000 Hz high-speed sampling ensures reproducible measurements for both peak measurement and graphing. Some functions require connection to separately-sold products.
- High sampling rate (2000Hz) for accurate results, capturing small changes and accurate peak values by following rapid changes of force
- Ideal for integration into facilities due to the box-shaped design and separated sensor
- A wide range of load cell available to meet various test applications (Adjustment is necessary when changing the sensor)
- Improves efficiency of testing using the equipped I/O functions for combining with external devices
- Next Series (Firmware Ver.5 or later) equips extended functions such as additional functions and software downloads from IMADA download site
Model | FA Plus2 | eFA Plus2 |
Features | Adjustment is required when change the load cell | Load cell interchangeable eZ Connect series (no need for adjustment) |
Accuracy | The accuracy of connected load cell | The accuracy of connected load cell + ±0.2% F.S. (*1) |
Unit of measurement | Depends on load cell and settings (N, kN, kgf, lbf, N-m, N-cm, kgf-m, kgf-cm, lbf-in, ozf-in)(*2) |
|
Display | 4-digit | |
Display update | 16 / sec | |
Sampling rate | 2000 data / sec at maximum (*3) | |
Battery | AC adapter(AC100~240V)(*4) | |
Operating environment | Temperature: 0~40 degree Celsius Humidity: 20~80%RH | |
Functions | Customized display (header and footer), Peak hold (tension and compression), Comparator (judgment of OK or NG), Display of AD value, Reversible display, Zero clear timer, +NG alarm, Off timer (auto power off), Dumping, Time display, 1st/2nd peak, Displacement detection at force peak value, Displacement zero reset at selected force, setting lock | |
Output | RS232C (baud rate available from 57600bps to 9600bps), USB, 2 VDC analog output (D/A), Comparator 3 steps (-NG/OK/+NG), Overload alarm, Sub comparator 2 steps (output of large or small judgment), USB flash drive, Displacement. | |
Overload warning | Approx.110%F.S. (Warning message and alarm) | |
Available liner scales | Online driver output (a line receiver according to RS422/485 must be built in.) Open collector output (Voltage drop between contacts must be smaller than 0.5V.) |
|
Weight | 1100g | |
Dimensions | Refer to dimensions | |
Accessories | AC adapter (only for standard model), Force Logger (software for data logging) (*5), USB cable, Adapter for USB flash drive (*6), Instruction manual | |
Inspection certification | – (*7) |
Application
- High sampling rate (2000Hz) for accurate results, capturing small changes and accurate peak values by following rapid changes of force
- Ideal for integration into facilities due to the box-shaped design and separated sensor
- A wide range of load cell available to meet various test applications (Adjustment is necessary when changing the sensor)
- Improves efficiency of testing using the equipped I/O functions for combining with external devices
- Next Series (Firmware Ver.5 or later) equips extended functions such as additional functions and software downloads from IMADA download site
Specifications
Model | FA Plus2 | eFA Plus2 |
Features | Adjustment is required when change the load cell | Load cell interchangeable eZ Connect series (no need for adjustment) |
Accuracy | The accuracy of connected load cell | The accuracy of connected load cell + ±0.2% F.S. (*1) |
Unit of measurement | Depends on load cell and settings (N, kN, kgf, lbf, N-m, N-cm, kgf-m, kgf-cm, lbf-in, ozf-in)(*2) |
|
Display | 4-digit | |
Display update | 16 / sec | |
Sampling rate | 2000 data / sec at maximum (*3) | |
Battery | AC adapter(AC100~240V)(*4) | |
Operating environment | Temperature: 0~40 degree Celsius Humidity: 20~80%RH | |
Functions | Customized display (header and footer), Peak hold (tension and compression), Comparator (judgment of OK or NG), Display of AD value, Reversible display, Zero clear timer, +NG alarm, Off timer (auto power off), Dumping, Time display, 1st/2nd peak, Displacement detection at force peak value, Displacement zero reset at selected force, setting lock | |
Output | RS232C (baud rate available from 57600bps to 9600bps), USB, 2 VDC analog output (D/A), Comparator 3 steps (-NG/OK/+NG), Overload alarm, Sub comparator 2 steps (output of large or small judgment), USB flash drive, Displacement. | |
Overload warning | Approx.110%F.S. (Warning message and alarm) | |
Available liner scales | Online driver output (a line receiver according to RS422/485 must be built in.) Open collector output (Voltage drop between contacts must be smaller than 0.5V.) |
|
Weight | 1100g | |
Dimensions | Refer to dimensions | |
Accessories | AC adapter (only for standard model), Force Logger (software for data logging) (*5), USB cable, Adapter for USB flash drive (*6), Instruction manual | |
Inspection certification | – (*7) |